Carrier 58RAV manual: Troubleshooting Guide. Download and print this document. Read and prints without ads; Download to keep your version. Models. 58PAV; 58RAV; Contents. 58PAV, 58RAV Induced-Combustion Furnaces Service and Maintenance Instructions. For Sizes , Series Fig. 1Model 58RAV Horizontal. · check the basic things i listed above, check the filter and blower wheel for cleanliness and the vents to see if they are blocked or anything restricting airflow. also since the high limit switch is automatic reset it should turn the burners on after it cools down. to reset the error 33 turn the power off to the furnace for 90 seconds and then turn it back on. if the burners do not come back on within 3 .
Posts. #3 · . Hi Mudtruck, To determine if it is code 13 or The first digit is the number of short flashes, the second digit is the number of long flashes. 13 is limit circuit lockout, in which case your furnace would try and restart after 3 hours. The limit circuit is there to protect the furnace from overheating if there. Looking at the diagram in the manual, it looks like it's the "draft safeguard tube and switch" that keeps turning off rather than the manual reset limit switches, and pushing it back in again resolves the issue. I follow the manual furnace shut down/start up procedure each time. It's a Carrier 58RAV down flow/horizontal furnace. Carrier 58PAV, 58RAV SERVICE, COMPONENT TEST. Fig. 13Service Label, SERVICE, COMPONENT TEST, TROUBLESHOOTING GUIDE, LED CODE, STATUS, SERVICE LABEL rollout switch requires manual reset. Refer to # 58PAV, 58RAV Induced-Combustion Furnaces Service and Maintenance Instructions. For Sizes , Series
Carrier 58RAV User Manual. Download. Like. Full screen Standard. Page of 12 Go. Never operate unit without a filter or with filter access door removed. Before operating the furnace, check each manual reset switch for 2. Cooling mode continuity. If necessary, press the button to reset the switch. When the thermostat "calls for cooling," R-G and R-Y circuits The blower compartment door must be in place to complete the close. Page Adjustments (3.) Verify furnace model. check the basic things i listed above, check the filter and blower wheel for cleanliness and the vents to see if they are blocked or anything restricting airflow. also since the high limit switch is automatic reset it should turn the burners on after it cools down. to reset the error 33 turn the power off to the furnace for 90 seconds and then turn it back on. if the burners do not come back on within 3 minutes then replace the high limit switch.
0コメント